@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix constant: <http://qudt.org/vocab/constant/> .
@prefix dc: <http://purl.org/dc/elements/1.1/> .
@prefix dcterms: <http://purl.org/dc/terms/> .
@prefix prov: <http://www.w3.org/ns/prov#> .
@prefix qkdv: <http://qudt.org/vocab/dimensionvector/> .
@prefix quantitykind: <http://qudt.org/vocab/quantitykind/> .
@prefix qudt: <http://qudt.org/schema/qudt/> .
@prefix si-quantity: <https://si-digital-framework.org/quantities/> .
@prefix skos: <http://www.w3.org/2004/02/skos/core#> .
@prefix unit: <http://qudt.org/vocab/unit/> .
@prefix vaem: <http://www.linkedmodel.org/schema/vaem#> .
@prefix voag: <http://voag.linkedmodel.org/schema/voag#> .

quantitykind:AbsorbedDoseRate
  a qudt:QuantityKind ;
  dcterms:description "\"Absorbed Dose Rate\" is the absorbed dose of ionizing radiation imparted at a given location per unit of time (second, minute, hour, or day)."^^qudt:LatexString ;
  qudt:applicableUnit unit:ERG-PER-GM-SEC ;
  qudt:applicableUnit unit:GRAY-PER-HR ;
  qudt:applicableUnit unit:GRAY-PER-MIN ;
  qudt:applicableUnit unit:GRAY-PER-SEC ;
  qudt:applicableUnit unit:MicroGRAY-PER-HR ;
  qudt:applicableUnit unit:MicroGRAY-PER-MIN ;
  qudt:applicableUnit unit:MicroGRAY-PER-SEC ;
  qudt:applicableUnit unit:MicroSV-PER-HR ;
  qudt:applicableUnit unit:MicroSV-PER-MIN ;
  qudt:applicableUnit unit:MicroSV-PER-SEC ;
  qudt:applicableUnit unit:MilliGRAY-PER-HR ;
  qudt:applicableUnit unit:MilliGRAY-PER-MIN ;
  qudt:applicableUnit unit:MilliGRAY-PER-SEC ;
  qudt:applicableUnit unit:MilliRAD_R-PER-HR ;
  qudt:applicableUnit unit:MilliSV-PER-HR ;
  qudt:applicableUnit unit:MilliSV-PER-MIN ;
  qudt:applicableUnit unit:MilliSV-PER-SEC ;
  qudt:applicableUnit unit:MilliW-PER-MilliGM ;
  qudt:applicableUnit unit:NanoGRAY-PER-HR ;
  qudt:applicableUnit unit:NanoGRAY-PER-MIN ;
  qudt:applicableUnit unit:NanoGRAY-PER-SEC ;
  qudt:applicableUnit unit:NanoSV-PER-HR ;
  qudt:applicableUnit unit:NanoSV-PER-MIN ;
  qudt:applicableUnit unit:NanoSV-PER-SEC ;
  qudt:applicableUnit unit:REM-PER-SEC ;
  qudt:applicableUnit unit:SV-PER-HR ;
  qudt:applicableUnit unit:SV-PER-MIN ;
  qudt:applicableUnit unit:SV-PER-SEC ;
  qudt:applicableUnit unit:W-PER-GM ;
  qudt:applicableUnit unit:W-PER-KiloGM ;
  qudt:hasDimensionVector qkdv:A0E0L2I0M0H0T-3D0 ;
  qudt:iec61360Code "0112/2///62720#UAD001" ;
  qudt:informativeReference "http://www.answers.com/topic/absorbed-dose-rate"^^xsd:anyURI ;
  qudt:informativeReference "https://cdd.iec.ch/cdd/iec62720/iec62720.nsf/ListsOfUnitsAllVersions/0112-2---62720%23UAD001"^^xsd:anyURI ;
  qudt:isoNormativeReference "http://www.iso.org/iso/catalogue_detail?csnumber=31895"^^xsd:anyURI ;
  qudt:latexDefinition "$\\dot{D} = \\frac{dD}{dt}$, where $dD$ is the increment of absorbed dose during time interval with duration $dt$."^^qudt:LatexString ;
  qudt:latexSymbol "$\\dot{D}$"^^qudt:LatexString ;
  qudt:plainTextDescription "\"Absorbed Dose Rate\" is the absorbed dose of ionizing radiation imparted at a given location per unit of time (second, minute, hour, or day)." ;
  qudt:siExactMatch si-quantity:ABDR ;
  qudt:wikidataMatch <http://www.wikidata.org/entity/Q69428958> ;
  rdfs:comment "Applicable units are those of quantitykind:AbsorbedDoseRate" ;
  rdfs:isDefinedBy <http://qudt.org/3.2.1/vocab/quantitykind> ;
  rdfs:label "Absorbed Dose Rate"@en .
